• Standard Cartridge Seals

CTX Dual Seals

  • Dual seal configuration
  • Balanced design
  • Independent of direction of rotation
  • Cartridge construction
  • Double pressure balanced
  • Designed with integrated pumping device for increased efficiency in circulation
  • Special design available for eccentric screw pumps

Details

  • 1

    Seal face

  • 2, 5, 7, 10, 13 15

    O-Ring

  • 11

    Spring

  • 12

    Seat

  • 6

    Shaft sleeve

  • 8

    Cover

  • 9

    Seal face

  • 14

    Drive collar

  • 16

    Set screw

  • 17

    Snap ring

  • 18

    Assembly fixture

  • 19

    HSH Cap Screw

  • 20

    Gasket

  • 21

    Screw plug

  • 22

    Gasket

  • Ideal for use in process pump standardization
  • O-ring is dynamically loaded to prevent shaft damage.
  • Dimensional modification of the stuffing box chamber is not required due to short radial installation height
  • Ideal to convert and retrofit pumps with packings and large volume OEM production
  • Cartridge unit factory assembled for easy installation, which reduces down- time
  • Rugged design for long operating life
  • Chemical industry
  • Food and beverage industry
  • Petrochemical industry
  • Pharmaceutical industry
  • Universally applicable
  • Water and waste water technology
  • Centrifugal pumps
  • Eccentric screw pumps
  • Seal face: Silicon carbide (Q1), Carbon graphite resin impregnated (B), Tungsten carbide (U2)
  • Seat: Silicon carbide (Q1)
  • Secondary seals: FKM (V), EPDM (E), FFKM (K), Perfluorocarbon rubber/PTFE (U1)
  • Springs: Hastelloy® C-4 (M)
  • Metal parts: CrNiMo steel (G), CrNiMo cast steel (G)
  • Sizes: d1 = Upto 100 mm (Upto 4.000’’)
    Other sizes on request
    Temperature: t= – 40 °C … +220 °C
    (- 40 °F … +428 °F)
    (Check O-ring resistance)
  • Sliding face material combination BQ1
    Pressure: p1 = 25 bar (363 PSI)
    Speed = 16 m/s (52 ft/s)
  • Sliding face material combination Q1Q1 or U2Q1
    Pressure: p1 = 20 bar (290 PSI)
    Speed = 10 m/s (33 ft/s)
    Barrier fluid circulation system:
    p3max = 25 bar (363 PSI)
    Δp (p3 – p1 ) ideal = 2 … 3 bar (29 … 44 PSI),
    7 bar (102 PSI) for barrier media with poor
    lubricating properties)
    Pump startup:
    Δp (p3 – p1 )max = 25 bar (363 PSI) allowed
    Recommended supply medium: max. ISO VG 5
    Permissible axial movement: ± 1.0 mm,
    d1 ≥ 75 mm ± 1.5 mm

Other products